# Master 2.32.1

<time class="date-past" datetime="2023-04-20">Released 20.04.2023</time>

### New features

<div class="conf-macro output-block" data-hasbody="true" data-macro-name="numberedheadings" id="bkmrk-%D0%A4%D1%83%D0%BD%D0%BA%D1%86%D0%B8%D1%8F-gen7-e96bt-e"><div class="table-wrap"><table class="fixed-table wrapped confluenceTable" style="width: 93.3333%; height: 128.586px;"><colgroup><col style="width: 55.6878%;"></col><col style="width: 7.14286%;"></col><col style="width: 8.06878%;"></col><col style="width: 9.65608%;"></col><col style="width: 9.65608%;"></col><col style="width: 9.92063%;"></col></colgroup><tbody><tr style="height: 46.5938px;"><th style="background-color: rgb(194, 224, 244); height: 46.5938px;">Feature</th><th class="confluenceTh" colspan="1" style="height: 46.5938px;">GEN7</th><th class="confluenceTh" style="height: 46.5938px;">E96BT</th><th class="confluenceTh" colspan="1" style="height: 46.5938px;">E96 (v2)</th><th class="confluenceTh" colspan="1" style="height: 46.5938px;">S96 (v2)</th><th class="confluenceTh" colspan="1" style="height: 46.5938px;">M18 mini</th></tr><tr style="height: 35.3984px;"><td class="confluenceTd" colspan="1" style="height: 35.3984px;">Siren control tone type setting added

</td><td class="confluenceTd" colspan="1" style="height: 35.3984px;">●</td><td class="confluenceTd" colspan="1" style="height: 35.3984px;">●</td><td class="confluenceTd" colspan="1" style="height: 35.3984px;">●</td><td class="confluenceTd" colspan="1" style="height: 35.3984px;">●</td><td class="confluenceTd" colspan="1" style="height: 35.3984px;">  
</td></tr><tr style="height: 46.5938px;"><td class="confluenceTd" colspan="1" style="height: 46.5938px;">Emergency disarm code transmission added</td><td class="confluenceTd" colspan="1" style="height: 46.5938px;">  
</td><td class="confluenceTd" colspan="1" style="height: 46.5938px;">  
</td><td class="confluenceTd" colspan="1" style="height: 46.5938px;">  
</td><td class="confluenceTd" colspan="1" style="height: 46.5938px;">  
</td><td class="confluenceTd" colspan="1" style="height: 46.5938px;">●</td></tr></tbody></table>

</div></div>#### Siren control signal type setting added

<span style="background-color: rgb(191, 237, 210);">**<span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">GEN7</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96 BT</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96(V2)</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">S96(V2)</span>**</span>

A new option to select siren control signal type has been added to the main settings. Type 1 matches signal used before firmware version 2.28. Type 2 - to signal in firmware versions from 2.28 to 2.31.

[![Book 3.jpg](https://help.starline.ru/uploads/images/gallery/2025-05/scaled-1680-/book-3.jpg)](https://help.starline.ru/uploads/images/gallery/2025-05/book-3.jpg)

#### Emergency disarm code transmission added

<span style="background-color: rgb(191, 237, 210);">**<span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">M18 MINI</span>**</span>

Emergency disarm code added to welcome SMS message.

### Fixed bugs

<div class="conf-macro output-block" data-hasbody="true" data-macro-name="numberedheadings" id="bkmrk-2.x.x%C2%A0gen7%C2%A0e96-bt%C2%A0e9">1. **<span class="status-macro aui-lozenge aui-lozenge-error conf-macro output-inline" data-hasbody="false" data-macro-name="status" style="background-color: rgb(248, 202, 198);">2.X.X</span>** **<span style="background-color: rgb(191, 237, 210);"><span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">GEN7</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96 BT</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96(V2)</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">S96(V2)</span></span>** CAN sometimes stopped working (both reading status and controlling functions) until the main unit was restarted on single-wire vehicles.
2. **<span class="status-macro aui-lozenge aui-lozenge-error conf-macro output-inline" data-hasbody="false" data-macro-name="status" style="background-color: rgb(248, 202, 198);">2.31.1</span>** <span style="background-color: rgb(191, 237, 210);">**<span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">GEN7</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96 BT</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96(V2)</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">S96(V2)</span>**</span> The new flexible logic programs for 'start' and 'stop' events were not working correctly.
3. **<span class="status-macro aui-lozenge aui-lozenge-error conf-macro output-inline" data-hasbody="false" data-macro-name="status" style="background-color: rgb(248, 202, 198);">2.30.0</span>** **<span style="background-color: rgb(191, 237, 210);"><span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">E96(V2)</span> <span class="status-macro aui-lozenge aui-lozenge-success conf-macro output-inline" data-hasbody="false" data-macro-name="status">S96(V2)</span></span>** On some GM vehicles, bypass or immobilizer programming procedure does not work on main unit with serial numbers ES96P and E96V2P.

</div>### Known bugs

No

*This firmware is for security systems for serial numbers GEN7 S..., E96BT S..., E96V2 S..., ES96 S..., except for E96V2L S..., ES96L S...*