Light and sound indication The security complex provides various options for indicating modes such as "Disarmed", "Armed", and "Alarm": Hidden : Light and sound indicators are disabled. Silent : Only light indicators are enabled. Sound : Only sound indicators are enabled. Full : Both light and sound indicators are enabled. The default setting includes sound notifications with sirens and emergency light signals. The indicator mode is configured by the installation specialist during complex setup. Indicator table The security complex informs about its status by means of sound (horn) and light signals (turn signals): — short signal; — long signal. Event Light signals Horn Security activation Security activation with security zone breach Security deactivation Security deactivation (one of the zones was violated in the security cycle)       Alarm 30 s 30 s Warning level alarm Panic 10 s 10 s Trunk opening Exit from service mode LED Indicator System State LED Indicator Disarmed Not lit Disarmed with ignition and one zone violation (door, hood, trunk) Once every 5 seconds Armed Once per second Engine Running Constantly lit Service Mode Not lit "Trip Prohibition" Function Enabled Not lit Anti-hijacking Mode Enabled 10 times per second Incorrect Emergency Disarm Code Entered Four times Emergency Disarm Code Entry Blocked for 15 minutes Five times Correct Emergency Disarm Code Entered Twice Sound Indicator Event Sound Indicator Waiting for Authorization 10 seconds Successful Owner Authorization Code Input Incorrect Owner Authorization Code Input