# StarLine R6 ECO

# User Manual

#### **<span style="color: rgb(35, 111, 161);">General</span>**

<p class="callout info">The relay unit functionality described in this manual corresponds to the firmware version 1.1.0. If you upgraded device to the later version, find the actual manual at help.starline.bz</p>

The digital micro relay unit **StarLine R6 <span class="s1">ECO</span>** is intended to protect from a car theft by means of engine blocking. **StarLine R6 <span class="s1">ECO</span>** provides following benefits:

- compact size allows to hide it in a car original wiring
- waterproof housing and high quality components let it fit in any place of engine compartment in a high moisture and temperature conditions
- communication with a security system main unit is carried out via Bluetooth Smart (BLE) hack-proof secured protocol
- embedded accelerometer detects a motion to activate engine blocking.

<p class="callout info">The micro relay unit can be used with the following security systems: StarLine X96/X66, A96/B96/D96, StarLine AS96, StarLine E96/E66, StarLine S96/S66, StarLine i96CAN</p>

**StarLine R6 <span class="s2">ECO</span>** has 2 integrated relays. For each relay a blocking interval and delay can be configured. It makes possible to perform an engine blocking with 2 independent circuits interruption. The unit is always in wireless connection with a main security system unit and receives commands on engine blocking from it. In case of connection loss for any reason in a guard mode the relay unit shall independently block an engine.

#### <span style="color: rgb(35, 111, 161);">**Registration of Relay unit into security system** </span>

If **StarLine R6 <span class="s2">ECO</span>** is supplied separately from security systems, so it should be registered into main unit memory.

<p class="callout info">Up to 4 relays can be registered to one main unit</p>

Registration is carried out via wireless Bluetooth Smart (BLE) channel in following steps:

1. Disconnect input power from relay unit
2. Interconnect the white-black and yellow-red wires
3. Switch the security system into registration mode
4. Connect input power to the relay unit
5. Confirmation on successful registration will follow within 10 sec from security system
6. Disconnect the white-<span style="color: rgb(0, 0, 0);">black</span> and yellow-red wires

##### <span style="color: rgb(35, 111, 161);">**Registration into security systems StarLine A96, AS96, B96, D96, E96, E96BT, S96, X96(v2)**</span>

1. Disconnect input power from relay unit
2. Interconnect the white-black and yellow-red wires
3. Press the service button 7 times
4. Turn ignition On
5. 7 LED flashes and siren signals will confirm enter to registration mode
6. Connect input power to the relay unit
7. In 10 sec the successful registration will be confirmed with 2 LED flashes and siren signals
8. Disconnect the white-black and yellow-red wires


#### **<span style="font-family: -apple-system, 'system-ui', 'Segoe UI', Oxygen, Ubuntu, Roboto, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif; color: rgb(34, 34, 34); font-size: 1.666em;"><span style="color: rgb(35, 111, 161);">Tech</span></span><span style="font-family: -apple-system, 'system-ui', 'Segoe UI', Oxygen, Ubuntu, Roboto, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif; color: rgb(34, 34, 34); font-size: 1.666em;"><span style="color: rgb(35, 111, 161);">nical </span></span><span style="color: rgb(34, 34, 34); font-family: -apple-system, 'system-ui', 'Segoe UI', Oxygen, Ubuntu, Roboto, Cantarell, 'Fira Sans', 'Droid Sans', 'Helvetica Neue', sans-serif; font-size: 1.666em;"><span style="color: rgb(35, 111, 161);">specification</span></span>**

<div class="table-wrap" id="bkmrk--3"></div><table border="1" class="confluenceTable" id="bkmrk-%D0%9D%D0%B0%D0%BF%D1%80%D1%8F%D0%B6%D0%B5%D0%BD%D0%B8%D0%B5-%D0%BF%D0%B8%D1%82%D0%B0%D0%BD%D0%B8%D1%8F-%D0%B2" style="border-collapse: collapse; width: 76.2963%; height: 350.5px; border-color: rgb(0, 0, 0);"><tbody><tr style="height: 35.5156px;"><td class="confluenceTd" style="height: 35.5156px; border-color: rgb(0, 0, 0); width: 49.272%;">Input voltage

</td><td class="confluenceTd" style="height: 35.5156px; border-color: rgb(0, 0, 0); width: 50.8901%;"><span class="s1">5 </span>– 18 V

</td></tr><tr style="height: 35.3984px;"><td style="border-color: rgb(0, 0, 0); width: 49.272%; height: 35.3984px;">Current consumption

</td><td style="border-color: rgb(0, 0, 0); width: 50.8901%; height: 35.3984px;">1 mA

</td></tr><tr style="height: 57.7969px;"><td class="confluenceTd" style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 49.272%;">Power consumption

with relays On

</td><td class="confluenceTd" style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 50.8901%;">28 mA

</td></tr><tr style="height: 57.7969px;"><td style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 49.272%;">Permissible each relay

load current

</td><td style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 50.8901%;">up to 500 mA

</td></tr><tr style="height: 57.7969px;"><td class="confluenceTd" style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 49.272%;">Maximum permitted switched current via relay contacts

</td><td class="confluenceTd" style="height: 57.7969px; border-color: rgb(0, 0, 0); width: 50.8901%;">10 A</td></tr><tr style="height: 35.3984px;"><td class="confluenceTd" style="height: 35.3984px; border-color: rgb(0, 0, 0); width: 49.272%;">Operating temperature range

</td><td class="confluenceTd" style="height: 35.3984px; border-color: rgb(0, 0, 0); width: 50.8901%;">\- 40 ... +105 °С

</td></tr><tr style="height: 35.3984px;"><td style="border-color: rgb(0, 0, 0); width: 49.272%; height: 35.3984px;">Protection rate

</td><td style="border-color: rgb(0, 0, 0); width: 50.8901%; height: 35.3984px;">IP54

</td></tr><tr style="height: 35.3984px;"><td style="border-color: rgb(0, 0, 0); width: 49.272%; height: 35.3984px;">Dimensions

</td><td style="border-color: rgb(0, 0, 0); width: 50.8901%; height: 35.3984px;">62,5×14×10,5 mm

</td></tr></tbody></table>

<div class="table-wrap" id="bkmrk-%D0%9F%D0%B0%D1%80%D0%B0%D0%BC%D0%B5%D1%82%D1%80-%D0%97%D0%BD%D0%B0%D1%87%D0%B5%D0%BD%D0%B8%D0%B5-%D0%A1%D1%82"></div>#### **<span style="color: rgb(35, 111, 161);">General installation requirements</span>**

**StarLine R6 <span class="s2">ECO</span>** is dedicated to fit in vehicles with 12V onboard power supply. Place it in a hidden place (for example, inside original wiring in engine compartment), avoiding contact with the moving parts of a vehicle.  
Fix the unit with straps.

<div class="conf-macro output-block" data-hasbody="false" data-macro-name="include" id="bkmrk-%D0%B7%D0%B5%D0%BB%D0%B5%D0%BD%D1%8B%D0%B9-%E2%80%94%C2%A0%D0%B2%D1%8B%D0%BA%D0%BB%D1%8E%D1%87%D0%B5%D0%BD-%D1%80"></div>**Power circuits connection**

The red (+12V) and black (ground) wires are used for power supply connection.

The black ground wire must be connected first to the factory screw or nut on the body. The wire should be crimped into the matching size electric clamp before fixing under screw or nut. Do not use tapping screws and other non-original fasteners for the ground wire connection.

Cover the place of connection with anti-rust grease.

Connect the red +12V wire to original constant power supply circuits wires with cross section not less than 2 sq.mm or connect directly to the main battery clamp.

The red wire should be connected through the fuse from delivery set.

##### **<span style="color: rgb(35, 111, 161);">Connection diagram</span>**

[![StarLine_R6ECO_Connection diagram.png](https://help.starline.ru/uploads/images/gallery/2026-08/scaled-1680-/MH5starline-r6eco-connection-diagram.png)](https://help.starline.ru/uploads/images/gallery/2026-08/MH5starline-r6eco-connection-diagram.png)