Parameter | Value |
---|---|
Frequency range of control radio signals, GHz | 2.4 |
Type of control code | dialogue |
Maximum coverage range | up to 10 meters (*) |
Ingress Protection | IP67 |
Supply Voltage, V | 9–16 |
Consumption current with switched-off ignition, mA |
|
Consumption current with switched-on ignition, mA | 6.8 (**) |
Maximum current load via relay contacts, A | 10 |
Maximum current load at hood lock outputs, A | 20 |
Operating temperature range, °С | from −40 to +125 |
(**) — with engine blocking inactive
Indication module
Parameter | Value |
---|---|
Frequency range of control radio signals, GHz | 2.4 |
Type of control code | dialogue |
Maximum coverage range | up to 10 meters (*) |
Ingress Protection | IP67 |
Supply Voltage, V | 9–16 |
Consumption current with switched-off ignition, mA | 0.01 |
Operating temperature range, °С | from −40 to +85 |
(*) — depends on location of the immobilizer components
Tag
Parameter | Value |
---|---|
Frequency range of control radio signals, GHz | 2.4 |
Type of control code | dialogue |
Maximum coverage range | up to 10 meters (*) |
Ingress Protection | IP67 |
Supply Voltage, V | 3.3 |
Operating temperature range, °С | from −20 to +70 |
Battery type | CR2025, CR2032 |
Battery life time | up to 12 months |